Gorilla.Audio.STT.VAD Unit Reference

Overview

The Gorilla.Audio.STT.VAD unit contains the voice activity detection of the speech recognition subsystem: the backend independent IGorillaVAD interface, the TGorillaVADBase state machine, the energy based detector registered by default, and the registry that makes detectors selectable by name.

A detector is stateful and belongs to exactly one audio stream, so every listener creates its own instance. Feed() is called from the capture thread, everything else from the same thread.

Class Hierarchy

TInterfacedObject
  └── TGorillaVADBase (IGorillaVAD)
        └── TGorillaEnergyVAD

TGorillaVADRegistry (class with class methods only)

Enumerations

TGorillaVADState

Value Description
Silence No speech, the noise floor is being tracked
Speech Speech is running, samples are collected

Records

TGorillaVADSegment

One complete utterance cut out of the microphone stream.

Field Description
Samples 16 kHz mono float samples of the utterance
StartTime Start of the utterance in the stream, in seconds
EndTime End of the utterance in the stream, in seconds
PeakLevel Loudest sample of the utterance, 0..1
AverageLevel Average level of the utterance, 0..1
Truncated True when the maximum length forced the cut
Duration() Length of the utterance in seconds
IsValid() True when the segment carries audio

IGorillaVAD

Method Description
GetName() Human readable name of the detector
IsAvailable() False when the detector cannot work, e.g. a missing library
Configure(ASampleRate) Prepares the detector for a stream of that rate; resets all state, so it may be called again whenever the capture format changed
Reset() Drops the collected audio and returns to silence
Feed(ASamples, ACount) Pushes new samples in; returns the number of segments completed during this call
Flush() Closes a running utterance immediately, e.g. when push-to-talk was released; returns the number of completed segments
TakeSegment(out ASegment) Removes the oldest completed segment from the queue; false when none is waiting
PendingSegments() Number of segments waiting
GetState() Current TGorillaVADState
GetLevel() Current input level, 0..1
GetNoiseFloor() Tracked noise floor
GetStreamTime() Position in the stream, in seconds

TGorillaVADBase

Implements the state machine shared by all detectors: threshold handling, pre-roll buffer, minimum durations and the segment queue. A concrete detector only implements the per-frame classification.

Properties

Property Type Default Description
Threshold Single 0.012 Absolute level a frame has to exceed to count as speech. It acts as the lower bound of the adaptive threshold: the effective threshold is the larger of this value and NoiseFloor * NoiseMultiplier
NoiseMultiplier Single 2.5 Factor the tracked noise floor is multiplied with
MinSpeechDuration Single 0.25 Shortest utterance reported, in seconds; anything shorter is discarded as a click or a cough
MinSilenceDuration Single 0.6 Pause that ends an utterance, in seconds. Too short cuts sentences apart at every breath, too long adds latency to every result
PreRollDuration Single 0.3 Audio in front of the detected speech that is kept, in seconds; without it the plosive at the start of a word is cut off
MaxSegmentDuration Single 15.0 Emergency brake: an utterance is cut after this many seconds even when the speaker does not pause
Normalize Boolean — Normalizes the collected audio before it is reported

Protected Methods (for implementers)

Method Description
DoDetectFrame(ASamples, ...) Classifies one complete frame; true when it contains speech
DoConfigure() Called after Configure() so a detector can size its state
DoReset() Called by Reset() so a detector can drop its state
GetVADName() Name the detector registers itself under

TGorillaEnergyVAD

The default detector: frame energy against an adaptive threshold, with a zero crossing rate check to keep loud non-speech noise out. Registered under the name Energy with priority 0.

Property Type Default Description
MaxZeroCrossingRate Single 0.42 Crossing rate above which a loud frame is treated as noise, 0..1
NoiseAdaption Single 0.05 Speed the noise floor follows the input, 0..1; larger values adapt faster but are more easily fooled by slow speech

TGorillaVADRegistry

Class Method Description
RegisterVAD(AClass, APriority) Registers a detector with a priority
UnregisterVAD(AClass) Removes it again
FindVADClass(AName) Resolves a detector class by name
CreateVAD(AName) Creates an instance; an empty name picks the highest priority detector
VADNames() Names of all registered detectors
DefaultVADName() Name of the highest priority detector

Constants

Constant Value
GORILLA_VAD_THRESHOLD 0.012
GORILLA_VAD_NOISE_MULTIPLIER 2.5
GORILLA_VAD_MIN_SPEECH 0.25
GORILLA_VAD_MIN_SILENCE 0.6
GORILLA_VAD_PREROLL 0.3
GORILLA_VAD_MAX_SEGMENT 15.0
GORILLA_VAD_MAX_ZCR 0.42
GORILLA_VAD_NOISE_ADAPTION 0.05